Model:RODI-T2-H- High Capacity Reverse Osmosis plus Type II DI System
The 20-LPH reverse osmosis portion of this system reduces operating costs by economically removing ~95% of the contaminants from the incoming tap water. The RO water is stored in an included 42-Liter pressurized tank that prevents the risk of airborne contamination and eliminates the need for additional feed pumps and tank filters.
The Type II DI portion of this system produces 2-15 megohm-cm (0.48-0.067 MicroSeimens/cm) water at a flow rate of 5 Liters/minute and and includes two installed High Capacity DI Module and one spare DI Module. It features continuous recirculation to maintain maximum water purity. Therefore, pure water is instantly available on demand. The system includes a single dispensing valve and can be setup to feed several dispensing points via a small (50 linear foot) circulation loop. A variety of optional faucets, valves, and dispensers are available for use with the system.
This affordable lab water system is simple to install and is easily maintained by the user. The system cabinet can be bench, shelf or wall mounted and the RO storage tank can be installed up to 20 feet from the system. An additional RO membrane can be added to the system to increase RO production and the storage tank can be upgraded to increase capacity. The system has a 2-year warranty in most countries, is proudly made in the USA
High flow, high capacity versions of this system are also available. See Models: RODI-2000-01T2, or RODI-2000-03T2
This compact, combination Reverse Osmosis plus Type II DI System is for operation on virtually any quality tap water that contains less than 1,000 PPM of total dissolved solids.
All AQUA SOLUTIONS' Type II Systems produce purified water that exceeds ASTM, CAP and CLSI specifications for Type II reagent grade water.
Features and Benefits
- Made in the USA
- One (1) year warranty.
- Simple to install and easily maintained by the user
- Includes LCD readout conductivity monitor with flashing red LED alarm.
- The System price includes two High Capacity purification modules: one installed and one spare.
- Continuous recirculation is utilized to ensure water quality and prevent the growth of microorganisms within the system.
- Built-in Reverse Osmosis pretreatment lowers operating cost by economically removing 95-98% of the contaminants from the tap water.
- You can install the spare DI tank yourself, whenever you need it - even on weekends!
- Certified by CSA for the US & Canada, CE marked for export to EU countries.
- You purchase and own the system hardware at a reasonable cost.
Pure Water Specifications
Resistivity/Conductivity | >2 megohm-cm or |
Pure Water Grade | Type II |
DI Flow Rate | 5-LPM |
RO Production | 20-LPH |
Storage Capacity | RO, 42-Liters |
Feed Water
Feed Water Quality | For operation on any quality tap water containing less than 1,000 PPM of total dissolved solids. |
Water Connection | User supplied 1/4" or 3/8" NPTF valve (3/8" Tube X 1/4" NPTM & 3/8'" Tube X 3/8" NPTM fittings included with system) |
Features and Benefits
Purification DI Modules | The System price includes three purification modules: two installed and one spare |
Country of Origin | Made in the USA |
Recirculation | Continuous recirculation is utilized to ensure water quality and prevent the growth of microorganisms within the system. |
Purity Meter | Digital conductivity meter monitors the DI water quality. |
Alarm Set Point | The meter has a flashing red LED that alerts the user when the water quality drops below 0.48 MicroSiemen (2 megohm-cm). |
Ion Exchange Capacity | 6,000 Grains |
Warranty | 2 Year |
Certification | Certified by CSA for the US & Canada, CE marked for export to EU countries |
GSA | This item is on our GSA Contract # GS-07F-5799R |
Lower Operating Costs | Built-in Reverse Osmosis pretreatment lowers operating cost by economically removing 95-98% of the contaminants from the tap water. |
No monthly rental charges | You purchase and own the system hardware at a reasonable cost. |
No installation charges | The system is so easy to install, you can do it yourself. |
No service charges | You can install the spare DI tank yourself, whenever you need it - even on weekends! |
It puts you in control | If the DI tank exhausts in the middle of an experiment, or during a weekend, you can install the spare tank. |
Optional Upgrades
2700N | Remote Dispenser kit - non-recirculating type - with 0.22 micron final filter capsule |
2700N-NFC | Remote Dispenser kit - non-recirculating type - no final filter capsule |
2700R | Remote Dispenser kit - recirculating type - with 0.22 micron final filter capsule |
2701-DISP | DI Spray gun 1/4" NPTF inlet and spray pattern outlet 1-GPM |
2701-DISP-6 | DI Spray gun 3/8" NPTF inlet and spray pattern outlet 1-GPM |
CH1004-PF | 10" Pre-filter assembly with 5 micron sediment filter |
DC2002 | 1 inch 0.22 micron (absolute) Final Filter Capsule |
DC2004 | 2 inch 0.22 micron (absolute) Final Filter Capsule |
DC2022 | High flow 0.22 micron (absolute) Filter Capsule |
UV2006S | UV Sterilizer - Prevents the growth of microorganisms within the system. |
UF2000 | Ultrafilter - Removes Pyrogen, Endotoxin, RNase, & DNase |
RODI2-130TU-042 | Tank upgrade: Increases storage capacity from 42 to 130 Liters |
RODI2-200TU-042 | Tank upgrade: Increases storage capacity from 42 to 200 Liters |
ROT-200 | 200-Liter pressurized storage tank with valve assembly |
System Specifications
Cabinet dimension | Width - 20 in (508 mm), Depth - 12 in (305 mm) Height - 20 in (508 mm) |
Mounting | Bench, Shelf, or Wall (no additional charge) |
Operating weight | 75 - 100 lbs (34 - 45 kg) cabinet only |
Input Power | Requires a 110V outlet within 5 ft. of the purity sensor |
System power source | Switching power supply - 12 VDC at 2.5 Amps |
Minimum Inlet Pressure | 10 PSI (0.68 bar) |
Maximum Inlet Pressure | 10 PSI (6.8 bar) |
Consumables
2618DIR | Type 2 Resin Refill for 2618DI Module (Exchange) |
CC1050 | 10" 1-Micron Activated Carbon Prefilter |
CN1050MP | 10" 5-Micron Sediment Pre-Filter - For use with optional CH1004-PF |